OpenBuildings™ Station Designer Help

To define dimensions of a frame in a cavity wall

  1. From the Parametric Frame Builder dialog, select Set Thickness from the Action list box.
  2. Select Wall Interior from the Thickness option menu. Enter the thickness of the internal wall in the Thickness field.
  3. (Optional) Select Recess Horizontal from the Thickness option menu. Enter the value of the horizontal recess in the Thickness field.
  4. (Optional) Select Tolerance Horizontal from the Thickness option menu. Enter the value of the tolerance in the Thickness field.
  5. (Optional) Select Recess Vertical from the Thickness option menu. Enter the value of the vertical recess in the Thickness field.
  6. (Optional) Select Tolerance Vertical from the Thickness option menu. Enter the value of the tolerance in the Thickness field.